The function of voltage converter (inverter) is to convert low DC voltage into high AC voltage. Some electronic equipment must be driven by AC, but what we provide is DC power supply. At this time, it is necessary to use inverter to convert DC into AC before driving the electronic parts.


Relevant test conditions of voltage converter:

Initial test at normal temperature: 25 ℃, ≥ 2 hours

Low temperature initial test: 0 ℃ or -5 ℃, ≥ 2 hours

High temperature initial test: 60 ℃, ≥ 2 hours

High temperature and humidity test: 40 ℃ /95%rh, 240 hours

High temperature storage test: 70 ℃, ≥ 96 hours or 240 hours

Low temperature storage test -1:-20 ℃, ≥ 96 hours

Low temperature storage test -2:-40 ℃, 240 hours

High temperature and humidity storage test: 40 ℃ /90%rh, ≥ 96 hours

Temperature cycle test: -20 ℃ ~ 70 ℃, 5 cycles, room temperature ↓ -20 ℃ (4 hours) ↓ room temperature (90%rh.4 hours) ↓ 70 ℃ (4 hours) ↓ room temperature (4 hours)

High temperature load test: equivalent load at 55 ℃, 1000 hours

Life test: 40 ℃, MTBF ≥ 40000 hours

Note: the tested module should be placed under normal conditions (15 ~ 35 ℃, 45 ~ 65% RH) for one hour before testing